I�C was made to communicate over short distances between printed circuit boards and is a simple, 8-bit serial data bus. In the meantime, it isn’t only PCB-mountable pressure sensors that utilize the I�C signal for data transfer, but additionally pressure sensors remote from customer electronics.
Remote sensors usually have the advantage of being less sensitive to contaminated or aggressive media and having the ability to measure directly at the procedure. Regarding sensors mounted directly on the circuit board, the sensor element is, in many cases, exposed right to the medium. With remote sensors, steel or ceramic generally serve because the wetted surface.
I�C circuit
The I�C bus, alongside the two supply lines, requires only two further lines:
SCL (serial clock line)
SDA (serial data line)
Additional possibilities through I�C
The I�C bus is really a well-known standard in electronics, offering additional possibilities for communication with a pressure sensor than with an analogue signal:
In the info protocol, as well as the pressure value, a temperature value and diagnostic information (for example an integrity test of the data transfer) can be transmitted with a status byte.
Several pressure sensors could be connected to a bus line as ?slaves? to the customer electronics that functions as a ?master?.
On the client side, as opposed to the application of pressure sensors with analogue signals, the analogue-to-digital conversion of the pressure value for further signal processing is unnecessary since the pressure value is already within digital form. This plays a part in faster and easier signal processing.
The electronics for communication can be constructed with standard components readily available on the market.
Often, I�C signal pressure sensors may also be optimised to take less energy, making them perfect for battery-powered applications. In the WIKA portfolio, for instance, this pertains to the MPR-1 pressure sensor module.
Boundary conditions with the use of I�C
Since I�C is not a fieldbus, long wire lengths aren’t recommended. The utmost wire length depends, in detail, on the operating environment and the corresponding disturbing influences. I�C communication is best used in projects where the pressure sensor or the pressure sensor module is integrated into the customer product and therefore protected against external influences. Gleeful should also be noted that with any digitally processed signal, the response time due to discrete-time sampling will be somewhat slower than for an analogue, continuous signal.
Note
Your contact person will be happy to help you with any more questions on digital interfaces.
Distributed Intelligence
Distributed Intelligence on the integration of pressure sensors into hydraulic systems